Skip to content

Envirosun Products

Australia's most complete hot water range. Backed like no other.

Solar, heat pump, gas — whatever your water heating needs, Envirosun has a system for it. Every product is Australian-designed for Australian conditions, backed by industry-leading 10-year transferable warranties* and engineered to ensure serious long-term savings. One range. One local team. No runaround.

Products

Which Envirosun product best suits my needs?

Every property is different. Match the right system fast.

Product Category Capacity Suits Energy Savings Install Type Specifications
TS Range Solar Hot Water 167 – 304L 2–6 people Up to 80%+ Roof-mounted thermosiphon
AS Active Split Range Solar Hot Water 320 – 420L 3–6 people Up to 87% Ground tank / roof panels
HP Plus M9 - 200 / 330 Heat Pumps 190L · 330L 2–4 · 4–6 people Up to 73% Ground-mounted
HP Classic 250 Heat Pumps 246L 3–5 people Up to 71% Ground-mounted
CF Endless Series Natural Gas Gas Systems Continuous Any size 6.2-star rated Wall-mounted
CF Endless Series — LPG Gas Systems Continuous Any size 6.2-star rated Wall-mounted
Envirosun Heat Pumps Range
Specification HP PLUS M9 200 HP PLUS M9 330 HP 250 CLASSIC
GENERAL
Full model number ES200M9 ES330M9 250ES1-15
Total water capacity 190L 330L 246L
Rated voltage / frequency 220-240V/50Hz 220-240V/50Hz 220-240V/50Hz
Tank max pressure 850kPa 850kPa 850kPa
Corrosion protection Magnesium rod Magnesium rod Magnesium rod
Waterproof grade IPX4 IPX4 IPX4
PERFORMANCE (20°C/15°C AMBIENT AIR TEMPERATURE, 15°C–55°C WATER TEMPERATURE)
Power input of electric element 1500W 1500W 1500W
Rated power input of heat pump 780W 820W 495W
Maximum power input of heat pump 1500W 1500W 865W
Maximum power input 1500W 1500W 1500W
Average heating capacity by heat pump 3200W 3300W N/A
Default temperature setting 60°C 60°C 55°C
Temperature setting range – with heater 60°C – 75°C 60°C – 75°C 35°C – 75°C
Max working pressure of refrigerant 1.0/3.3MPa 1.0/3.3MPa 0.8/2.8MPa
Refrigerant type / weight R290/0.42kg R290/0.47kg R134a / 0.9kg
Sound pressure level @ 2m 42dB(A) 42dB(A) 46dB(A)
Ambient temperature for heat pump and element -7–45°C -7–45°C N/A
Ambient temperature for heat pump -7–45°C -7–45°C -7–45°C
PHYSICAL
Water inlet and outlet connection Rp ¾" Rp ¾" G3/4" F
TPR valve connection Rp ¾" Rp ¾" G3/4" F
Drain & Water inlet connection Rp ¾" Rp ¾" G3/4" F
Product Dimensions 580 x 620 x 1746mm 710 x 740 x 1923mm 600 x 629 x 1987mm
Packing dimension with pallet 695 x 685 x 2060mm 745 x 745 x 2263mm 736 x 695 x 2250mm
Net/Gross weight 93/119kg 119/148kg 102/118kg
Filled weight of the appliance 282kg 449kg TBC
Envirosun Solar Hot Water Range
Specification TS300 TS300 TS170 THX300
SYSTEM
Model TS300/40Se TS300/60Se TS170/40Se THX300/40Se
CER code TS300/40/O/E24/S2/E20HS TS300/60/O/E24/S2/E20HS TS170/20/O/E24/S2/E20HS TS300/40/C/E24/S2/E20HS
Storage capacity 304L 304L 167L 304L
Mass empty 129kg 144kg 76kg 135kg
Mass full 437kg 453kg 251kg 454kg
Footprint 2,238 x 2,600mm 3,260 x 2,600mm 1,400 x 2,600mm 2,238 x 2,600mm
Boost capacity 140L 140L 140L 140L
TANK
Model TS300/O/E24/S2 TS300/O/E24/S2 TS170/O/E24/S2 TS300/C/E24/S2
Mass empty 59kg 59kg 38kg 77kg
Mass full 363kg 363kg 206kg 393kg
Footprint 650 x 2,150mm 650 x 2,150mm 650 x 1,264mm 650 x 2,150mm
Height 600mm 600mm 600mm 600mm
COLLECTORS
Model E20HS E20HS E20HS (E20HA optional) E20HS
Quantity 2 3 1 2
Mass empty (each) 27.5kg 27.5kg 27.5kg 27.5kg
Mass full (each) 29.2kg 29.2kg 29.2kg 29.2kg
Footprint (each) 1,235 x 2,000mm 1,235 x 2,000mm 1,060 x 2,000mm 1,235 x 2,000mm
Height 70mm 70mm 70mm 70mm
ELECTRIC BOOSTER
Rating 2.4kW 2.4kW 2.4kW 2.4kW
Envirosun Gas Systems Range
Specification Endless Series Natural Gas Endless Series Natural Gas Endless Series LPG Endless Series LPG
Model ES20CF-2-NG ES26CF-2-NG ES20CF-2-LPG ES26CF-2-LPG
Gas Type Natural Gas Natural Gas LPG* LPG*
Normal Gas Consumption (MJ/h) 160 195 160 195
Water Pressure Max. (kPa) 1,000 1,000 1,000 1,000
Water Pressure Min. (kPa) 150 150 150 150
Gas Inlet Pressure (kPa) 1.13 - 5.0 1.13 - 5.0 2.0 - 3.5 2.0 - 3.5
Test Point Pressure (Pa) 580 / 150 800 / 150 920 / 320 1600 / 320
Number of Injectors 13 13 13 13
Diameter of Injector (mm) Ø2.15 Ø2.15 Ø1.3 Ø1.3
Burner Control Segment 7, 2, 4 7, 2, 4 7, 2, 4 7, 2, 4
Electrical Rating (W) 48 66 48 66
Anti-freezing Heating Capacity (W) 100 100 100 100
Heat Output (kW) 37 47 37 47
Water Heating Capacity at 25°C rise (L/min) 20 26 20 26
Water flow rate to activate the water heater (L/min) 2.3 2.3 2.3 2.3
Water flow rate to keep the water heater running (L/min) 1.7 1.7 1.7 1.7
Relief Valve Pressure Setting (MPa) 1.0-1.5 1.0-1.5 1.0-1.5 1.0-1.5
Ingress Protection Rating (AS 60529) IPX4 IPX4 IPX4 IPX4
Power Supply 220~240V/50Hz 220~240V/50Hz 220~240V/50Hz 220~240V/50Hz
Ignition Direct without pilot Direct without pilot Direct without pilot Direct without pilot
Gas Inlet Connection
Water Inlet & Outlet Connection
Net Weight / Gross Weight (kg) 19.7 / 22.2 19.7 / 22.2 19.7 / 22.2 19.7 / 22.2
Product Dimensions (mm) 590 × 370 × 210 590 × 370 × 210 590 × 370 × 210 590 × 370 × 210
Package Dimensions (mm) 712 × 425 × 298 712 × 425 × 298 712 × 425 × 298 712 × 425 × 298
* USE ONLY WITH PROPANE GAS. PROPANE-BUTANE GAS BLENDS (ULPG) ARE NOT SUITABLE FOR THIS MODEL

Right here for Aussie plumbers.

Just good, local expertise on tap. No offshore call centres. No runaround.